Air driven high pressure pumps for applications up to 4,000 bar (58,000 psi) M...-3 series

Maximator pumps of the M...-3 series are available in single-acting design with three air drive pistons. The maximum air drive pressure is 10 bar (145 psi).

Features high pressure pumps M...-3 series

  • single acting
  • three air drive pistons
  • Operating pressures of up to 4,000 bar (58,000 psi)

M...-3 pumps in single-acting design with three air drive pistons achieve three times the operating pressure of single-acting, single air drive section M pumps with the same drive pressure.

M...-3 pumps are available with polyurethane seals. They come standard with bottom inlet, side inlet is available as option.

Options for M...-2 (-3) series

  • Seal material for oil use (standard pump): Order code: M189-(2)(3)(L)
  • Special seal material to handle special fluids: Order code: See fluid compatibility guide
  • Side inlet for single acting versions: Order code: M189-(2)(3)(L) - S
  • Special inlet and outlet ports e.g. with BSPP or NPT thread
  • Air control unit for M series with filter pressure regulator, control pressure gauge and shut-off valve: Order code: M189-(2)(3) with C1
  • Spring return and hand lever attachment: (modification only available for M22 to M189 single acting, single air drive head types) Order code: M37 - 01H
  • Special inlet and outlet ports (i. e. NPT): M37 - NPT
  • Air control unit for M series with filter pressure regulator, control pressure gauge and shut-off valve: Order code: M37 with C1
  • To protect the pump against excessive outlet pressures, an air safety valve can be fitted to the air control unit: Order code: M189-(2)(3) with C1/SVair (The outlet pressure has to be indicated.)

Other options available on request.